Domus 3 combines alternating pressure redistribution and static therapy modes for improving pressure relief care and reducing the caregiver's workload during patient handling procedures, such as dressing changes and repositioning. The weight indicator dial on the pump interface allows quick and easy adjustment to match the support surface pressure firmness to the patient's weight distribution.
Alternating pressure redistribution system — Simplify procedure and workload for administering pressure relief care and pressure ulcer prevention.
Reducing pressure injuries for long-term care — Increasing skin activity and improving blood circulation with alternating pressure.

Manage Airway & Fluid Tubing

Manage Airway & Fluid Tubing

Deflating individual air cells to guide proper airway and fluid tubing organization prevents potential obstructions or displacements to hemodialysis flow and catheters, reducing the burden on the caregiver's workflow.

Self-Monitor Therapy On-The-Go

Self-Monitor Therapy On-The-Go

SleepWell enables frequent travellers to self-monitor their daily scores and make adjustments with the built-in coaching, making it simple for patients to stay consistent in their sleep therapy and continue improving their therapy outcomes.

Improve Experience for Compliance

Improve Experience for Compliance

SleepWell allows care providers to provide patients with data-driven suggestions and treatment plans on-demand, increasing the patient's confidence and adherence in the first 90 days, critical for improving long-term therapy compliance.

Access Scores and Data Instantly

Access Scores and Data Instantly

Scores with a detailed score breakdown allow patients to evaluate therapy effectiveness and communicate concerns with their care providers, streamlining checkups, assessments. SleepWell includes information on parts replacement.

Prevent Pressure Injury Risks

Prevent Pressure Injury Risks

Combining a unique headrest (facial pillow, sculpted ear pocket, and alternation pressure), a personalized pressure care system (individual air cell deflation), and cell airflow tracking prevents pressure injury risks, improving patient outcomes.

Access to Controls via Interface

Access to Controls via Interface

Visual interface with LCD enables quick access to controls such as alternating and zone pressure settings, therapy timer, shoulder lift apparatus, and alarm system settings, simplifying patient care for caregiver across all experience levels.

Standard 100
Mattress Dimension 78.7 x 35.4 x 8 in 2000 x 900 x 200 mm
Mattress Weight 30.8 lb 14 kg
Maximum Patient Weight 550 lb 250 kg
Standard 200
Mattress Dimension 78.7 x 35.4 x 8 in 2000 x 900 x 200 mm
Mattress Weight 30.8 lb 14 kg
Maximum Patient Weight 550 lb 250 kg
Standard 300
Mattress Dimension 78.7 x 35.4 x 8 in 2000 x 900 x 200 mm
Mattress Weight 30.8 lb 14 kg
Maximum Patient Weight 550 lb 250 kg

Introductions

Prevent Pressure Injury Risks

Prevent Pressure Injury Risks

Combining a unique headrest (facial pillow, sculpted ear pocket, and alternation pressure), a personalized pressure care system (individual air cell deflation), and cell airflow tracking prevents pressure injury risks, improving patient outcomes.
Access Scores and Data Instantly

Access Scores and Data Instantly

Scores with a detailed score breakdown allow patients to evaluate therapy effectiveness and communicate concerns with their care providers, streamlining checkups, assessments. SleepWell includes information on parts replacement.

FAQ

What happens if no power source is available due to, for example, power outages and transportation?
Optima Prone's Transport Mode refers to the combination of:
After selecting the Supine Position Mode or Prone Position Mode, there is a 20-minute wait for the surface to reach max firmness. Will automatic detection be active during this time?
No. During this time, the Automatic Pressure Adjustment is inactive and will not be detecting the patient's weight.
What does it mean when air cells have cell-in-cell? What are their benefits?
Cell-in-cell design refers to encapsulating a firm air cell within a larger outer cell, doubling the effect of firmness and stability for patients. Wellell’s Optima Series, including Prone, uses air cells with the cell-in-cell design in the sacrum area to improve patient support and comfort during sitting positions and when patients leave and enter the bed.
What does the Shoulder Lifting Mode do?
The Shoulder Lifting Mode activates a mechanical apparatus that lifts and holds the patient's shoulders and chest upward, mimicking traditional prone positioning therapy's manual shoulder lifting procedure done by two or more caregivers. The lift helps release neck pressure that often leads to hyperextension injury and avoid spinal deformity body pains.
Any recommendations on the number of cells to deflate for each section and for heel relief?
Deflation should follow the location of the patient's vulnerable areas. Our recommendations are:
What materials are the air cells made from?
All air cells are made from Thermoplastic Polyurethanes (TPU). It is highly resistant to breaking down when in contact with water (hydrolysis), soft to touch, and minimizes friction and noise during patient movements.

Domus 1 & 2 Fake23

Alternating pressure redistribution system — Simplify procedure and workload for administering press...

Domus 1 & 2 Fake23

Domus 1 & 2 Fake68

Automating prone shoulder lifting and full-body pressure relief — Reducing workflow complexity and p...

Domus 1 & 2 Fake68

Domus 4 Fake23

Proned and intubated COVID-19 patients undergo prone treatments for an average of 5 hospital days. H...

Domus 4 Fake23

Domus 4 Fake49

Domus 3 combines alternating pressure redistribution and static therapy modes for improving pressure...

Domus 4 Fake49