Domus 1 & 2 Fake48

Domus 1 & 2 Fake48
Domus 1 & 2 Fake48
Domus 1 & 2 Fake48
Domus 1 & 2 Fake48
Domus 1 & 2 Fake48

Proned and intubated COVID-19 patients undergo prone treatments for an average of 5 hospital days. However, as proning results in a higher risk of developing pressure injuries (PI), these patients may require 3 more hospital days to treat PI-related complications,3,4 reducing the nurse-to-patient ratio further.5
Alternating pressure redistribution system — Simplify procedure and workload for administering pressure relief care and pressure ulcer prevention.
A staggering 75% of COVID-19 ICU patients require intensive treatments for severe respiratory distress involving mechanical breathing support.1 The 74% mortality rate from severe respiratory distress-associated COVID-19 cases2 overwhelms global healthcare systems, leading to a devastating shortage of resources and imposing complexity and burden on intensive care units and prone positioning therapy management.

Coach to Keep Motivated, Educated

Coach to Keep Motivated, Educated

SleepWell mobile app includes instant access to coaching that keeps patients motivated and educated at home and on the road, helping patients adopt healthier lifestyle habits, improve their therapy outcomes and quality of life.

Self-Monitor Therapy On-The-Go

Self-Monitor Therapy On-The-Go

SleepWell enables frequent travellers to self-monitor their daily scores and make adjustments with the built-in coaching, making it simple for patients to stay consistent in their sleep therapy and continue improving their therapy outcomes.

Simplify Head Repositioning

Simplify Head Repositioning

Mechanically supporting shoulder lifts while creating space below the patient's chin decreases the caregiver's workload and risk of obstructing airway tubing, allowing the single-caregiver to perform head repositioning safely and efficiently.

Manage Airway & Fluid Tubing

Manage Airway & Fluid Tubing

Deflating individual air cells to guide proper airway and fluid tubing organization prevents potential obstructions or displacements to hemodialysis flow and catheters, reducing the burden on the caregiver's workflow.

Improve Experience for Compliance

Improve Experience for Compliance

SleepWell allows care providers to provide patients with data-driven suggestions and treatment plans on-demand, increasing the patient's confidence and adherence in the first 90 days, critical for improving long-term therapy compliance.

Access to Controls via Interface

Access to Controls via Interface

Visual interface with LCD enables quick access to controls such as alternating and zone pressure settings, therapy timer, shoulder lift apparatus, and alarm system settings, simplifying patient care for caregiver across all experience levels.

Standard 100
Mattress Dimension 78.7 x 35.4 x 8 in 2000 x 900 x 200 mm
Mattress Weight 30.8 lb 14 kg
Maximum Patient Weight 550 lb 250 kg
Standard 200
Mattress Dimension 78.7 x 35.4 x 8 in 2000 x 900 x 200 mm
Mattress Weight 30.8 lb 14 kg
Maximum Patient Weight 550 lb 250 kg
Standard 300
Mattress Dimension 78.7 x 35.4 x 8 in 2000 x 900 x 200 mm
Mattress Weight 30.8 lb 14 kg
Maximum Patient Weight 550 lb 250 kg

Introductions

Manage Airway & Fluid Tubing

Manage Airway & Fluid Tubing

Deflating individual air cells to guide proper airway and fluid tubing organization prevents potential obstructions or displacements to hemodialysis flow and catheters, reducing the burden on the caregiver's workflow.
Self-Monitor Therapy On-The-Go

Self-Monitor Therapy On-The-Go

SleepWell enables frequent travellers to self-monitor their daily scores and make adjustments with the built-in coaching, making it simple for patients to stay consistent in their sleep therapy and continue improving their therapy outcomes.

FAQ

What does it mean when air cells have cell-in-cell? What are their benefits?
Cell-in-cell design refers to encapsulating a firm air cell within a larger outer cell, doubling the effect of firmness and stability for patients. Wellell’s Optima Series, including Prone, uses air cells with the cell-in-cell design in the sacrum area to improve patient support and comfort during sitting positions and when patients leave and enter the bed.
Does it automatically switch to alternating pressure after the Supine Position Mode or Prone Position Mode finishes?
Yes. Alternating pressure will automatically take over once the Supine Position Mode or Prone Position Mode deactivates after 20 minutes of operation.
What materials are the air cells made from?
All air cells are made from Thermoplastic Polyurethanes (TPU). It is highly resistant to breaking down when in contact with water (hydrolysis), soft to touch, and minimizes friction and noise during patient movements.
What happens if no power source is available due to, for example, power outages and transportation?
Optima Prone's Transport Mode refers to the combination of:

Domus 1 & 2 Fake48

Proned and intubated COVID-19 patients undergo prone treatments for an average of 5 hospital days. H...

Domus 1 & 2 Fake48

Domus 1 & 2 Fake75

A staggering 75% of COVID-19 ICU patients require intensive treatments for severe respiratory distre...

Domus 1 & 2 Fake75

Domus 3 Fake31

On average, 65 per 1000 adult inpatients develop pressure injuries (also known as pressure ulcers) a...

Domus 3 Fake31

Domus 3 Fake76

Optima Auto provides caregivers more control and personalization over air mattress firmness, an elem...

Domus 3 Fake76